Description
Solar inverter or PV inverter converts the variable direct current (DC) output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC) that can be fed into a commercial electrical grid or used by a local, off-grid electrical network. It is a critical balance of system (BOS)–component in a photovoltaic system, allowing the use of ordinary AC-powered equipment. Solar power inverters have special functions adapted for use with photovoltaic arrays, including maximum power point tracking and anti-islanding protection.
Solar inverters may be classified into three broad types:
1.Stand-alone inverters, used in isolated systems where the inverter draws its DC energy from batteries charged by photovoltaic arrays. Many stand-alone inverters also incorporate integral battery chargers to replenish the battery from an AC source, when available. Normally these do not interface in any way with the utility grid, and as such, are not required to have anti-islanding protection.
2.Grid-tie inverters, which match phase with a utility-supplied sine wave. Grid-tie inverters are designed to shut down automatically upon loss of utility supply, for safety reasons. They do not provide backup power during utility outages.
3.Battery backup inverters, are special inverters which are designed to draw energy from a battery, manage the battery charge via an onboard charger, and export excess energy to the utility grid. These inverters are capable of supplying AC energy to selected loads during a utility outage, and are required to have anti-islanding protection.
Type | SK-SU3000E | SK-SU3700E | SK-SU5000E |
Input(DC) | |||
Max.recommended DC power[W] | 3300 | 4000 | 5000 |
Max.DC voltage[V] | 550 | ||
Norminal DC operating voltage[V] | 360 | ||
Max.input current[A] | 12 | 12/12 | 12/12 |
Max.short circuit current[A] | 15 | 15/15 | 15/15 |
MPPT voltage range[V] | 125-530 | ||
No. of MPP trackers | 1 | 2 | 2 |
Strings per MPP tracker | 1 | 1 | 1 |
Output(AC) | |||
Norminal AC power[VA] | 3000 | 3680 | 4600 |
Max.AC power[VA] | 3300 | 3680 | 4999 |
Rated grid voltage(AC voltage range)[V] | 230(180 to 270) | ||
Rated grid frequency[Hz] | 50/60 | ||
Norminal AC current[A] | 13 | 16 | 20 |
Max.AC current[A] | 14.4 | 16 | 21.7 |
Displacement power factor | 0.8 leading to 0.8 lagging | ||
Total harmonic distortion(THD,rated power)[%] | <3 | ||
Load control | YES(optional) | ||
Output DC(Battery) | |||
Battery voltage range[V] | 40-60 | ||
Recommended battery voltage[V] | 48 | ||
Max. charging/discharging power[W] | 2500 | ||
Max. charging/discharging current[A] | 25 | ||
Communication interfaces | CAN/RS232 | ||
Reverse connect protection | YES | ||
EPS OUTPUT(WITH BATTERY) | |||
EPS rated power[VA] | 2000 | ||
EPS rated voltage[V],Frequency[Hz] | 230.50/60 | ||
EPS rated current[A] | 8.7 | ||
EPS peak power[W];Duration[s] | 1.5xRrated,10 | ||
Switch times[s] | <5 | ||
Total harmonic distortion(THD,linear load)[%] | <3 | ||
Parallel operation | NO | ||
EFFICIENCY | |||
MPPT efficiency[%] | 99.9 | ||
Euro efficiency[%] | 97.0 | ||
Max. efficiency[%] | 97.6 | ||
Battery charge/discharge efficiency[%] | 94.0 | ||
Power Consumption | |||
Standby consumption[W] | <7 | ||
ldle mode | YES | ||
Standard | |||
Safety | IEC62109-1;IEC62109-2;IEC62040-1 | ||
EMC | EN61000-6-1/EN61000-6-2/EN61000-6-3 | ||
Certification | VDE 4105/AS/NZS4777.2/C10 11/EEN50438-NL/EN50438-DK/OVE-ONORME 8001/G83,G59/CEI 0-21 | ||
Environment Limit | |||
Protection class | Ip20(indoor use) | ||
Operating temperature range[°C] | -10~+50(derating at 40) | ||
Altitude[m] | <2000 | ||
Storage temperature[°C] | -20~+60 | ||
Noise emission(typical)[dB] | <40 | ||
Over voltage category | III(electric supply side),II(PV side) |